How to Calculate and Select Materials for Warehouse Racking
News

How to Calculate and Select Materials for Warehouse Racking

2026-02-26

I. Steel Design Specifications

The design strength of steel cannot be directly based on the yield strength indicated by the grade, nor can it be directly based on the yield strength measured in actual tests. For example, Q235 hot-rolled steel strip has a grade-indicated yield strength of 235MPa, but the design value is only around 210MPa. The measured yield strength of the steel strip before it is processed into racking uprights can reach 265MPa or even higher. Under the premise of meeting certain testing cycles and statistical requirements, the measured value should be used (the reason for saying "should" is because European standards have this, while Chinese racking standards do not currently have specific provisions). The measured yield strength after processing into racking uprights can reach 295MPa or even higher. The strength increase due to the work hardening effect here cannot be used (because it is not effective across the entire cross-section).

II. Characteristics of Racking Components

1. Uprights

The cross-section of uprights is generally an open Ω shape. Its full cross-section, minimum net cross-section, equivalent cross-section, and effective cross-section characteristics all need to be accurately obtained to meet different calculation needs. The calculation of these cross-sectional properties is quite complex, especially the shear center coordinates, free torsional constant, and sector moment of inertia. Manual calculation is virtually impossible; specialized software is required. It is particularly important to note that when designing and verifying columns according to Chinese standards, one cross-sectional parameter, Uy, is unavoidable, and this parameter can currently only be calculated through manual integration.

2. Beam-Column Joints

At the intersection of beams and columns, the connection method is a hook. Structurally, this type of joint is neither a freely rotating hinge nor a rigid connection, but rather a semi-rigid connection, somewhere in between. The degree of semi-rigidity, i.e., the joint stiffness, has a significant impact on racking, especially flat warehouse racking systems without back bracing. It should be obtained through testing and then accurately applied to the calculations.

3. Column Base Joints

At the intersection of columns and the ground, the connection method is a base plate with bolts. This type of joint is also semi-rigid and should also be obtained through testing and then accurately applied to the calculations.

4. Upright Assembly

A column assembly is formed by connecting two uprights with a series of struts. The struts and uprights are typically connected by bolts. Gaps and deformation between bolts and bolt holes cause a reduction in the in-plane shear stiffness of the upright assembly compared to the theoretical value. The reduced shear stiffness should be used in calculations.

5. Back Tie Rod System

For racking systems with high height, heavy load-bearing capacity, and seismic resistance requirements, such as automated storage and retrieval systems (AS/RS), a back tie rod system is necessary. The back tie rod system includes back tie rods, horizontal tie rods, reinforced uprights, and tie rod connectors. For information on how to properly and effectively set up a back tie rod system, please refer to the published article: Requirements for Setting Up a Tie Rod (Support) System for AS/RS. If you find the article too lengthy, here are the conclusions:

a) Back braces must be equipped with reasonable and continuous horizontal braces to function effectively;

b) For single-row racks, if the back brace is not flush with the uprights but has a certain distance between it and the uprights, reinforced uprights must be installed. A horizontal beam should be installed between the two reinforced uprights corresponding to the back brace. A horizontal force-transmitting component, such as a horizontal cross brace or shear plate, should be installed between the horizontal beam and the rack beam;

c) Horizontal cross braces are also required at back-to-back rack positions.

6. Flexible Components

Because the back brace and horizontal brace have a large slenderness ratio, they cannot resist compression. Internal force analysis should consider that these components are only under tension, not compression; otherwise, the results will be biased.

How to Calculate and Select Materials for Warehouse Racking.jpg

III. Load Conditions

1. Load Offset of Storage Units

For beam racks, misalignment of palletized goods will cause uneven loading on a pair of beams, especially when the pallet depth is 200mm or more greater than the rack depth (European standard is 100mm). 1. If the eccentric load exceeds 12%, the overload of the beam bearing the greater load must be considered.

2. Unfavorable Arrangement of Storage Unit Loads

In addition to considering the case where all storage locations are fully loaded with storage units, it is also necessary to consider the unfavorable situation where some storage locations are unloaded on top of a fully loaded base, resulting in a slight decrease in the axial force of the uprights but a significant increase in bending moment.

3. Placement Loads

For placement loads caused by the storage and retrieval of goods by handling equipment, both longitudinal and lateral effects need to be considered separately.

4. Back Support Loads

When back supports are installed, if the design intention is to allow goods to contact the back supports, then the horizontal force exerted on the back supports must also be considered.

5. Defect Loads

The initial tilt of the entire racking system and the initial loosening between nodes will cause the vertical load to generate a horizontal component. This is the most important horizontal force causing racking collapse, therefore it must be strictly considered according to standards, both longitudinally and laterally.

6. Impact Loads

When designing components that directly bear goods, such as load-bearing beams and brackets, the dynamic impact loads from downward loading must be considered.

7. Accidental Loads

While the load from a forklift accidentally colliding with a rack upright should be avoided as much as possible, it is unavoidable for unprotected uprights. Therefore, an appropriate force should be considered in the horizontal direction.

8. Seismic Loads

For projects with seismic resistance requirements, calculations should be performed according to seismic design codes.

IV. Load Combinations

The above load cases are considered. Each case is not calculated individually, but rather combined according to standards using certain coefficients. For example, storage unit loads must be combined with defect loads, and storage unit loads must be combined with seismic loads, etc. During the combination process, it is necessary to distinguish:

a) Ultimate limit state and serviceability limit state;

b) Full load and unfavorable load arrangement;

c) Positive and negative directions of loads on asymmetrical structures.

V. Overall Internal Force Analysis

1. Finite Element Model

After load combination, the combined loads are applied to the rack, and the effects on each component of the rack are calculated. This is the internal force analysis. For very simple racks, this process can be completed manually. However, for slightly more complex racks, computer software is needed, specifically a technique called the finite element method (FEM). In the software, based on the rack drawings, considering the above material properties, component characteristics, load cases and combinations, a finite element model is created for the various analyses mentioned below.

2. Buckling Analysis

Before the formal internal force analysis, a buckling analysis can be performed. The results of the buckling analysis determine whether and how second-order effects need to be considered in the internal force analysis.

3. Nonlinear Analysis

Generally speaking, the buckling coefficient of a rack will not exceed 10, unless using high-specification uprights or placing extremely light goods, which is impractical. Therefore, both analysis and design must consider second-order effects; without considering second-order effects, the design results will be incorrect. All internal force analyses under various load combinations employ nonlinear analysis considering the P-Δ effect to fully account for second-order effects.

4. Seismic Force Calculation

Seismic force calculations utilize the modal response spectrum method, which is more accurate than the base shear method.

VI. Component Verification

The process of calculating the load-bearing capacity of each component to ensure it is not lower than the internal forces calculated above is called component verification. Once all components pass verification, the overall racking structure's load-bearing capacity is satisfied.

Currently, no software incorporates racking structure design standards into its code, making automatic component verification impossible. We strictly adhere to racking structure design standards, developing verification Excel spreadsheets for various component types and performing calculations and verifications one by one.

1. Uprights

The load-bearing capacity of uprights under simultaneous axial force and bending moment is verified, considering the impact of local buckling, distortional buckling, and flexural-torsional buckling on the stable load-bearing capacity.

2. Stud Joints

The struts themselves generally pass the verification, but the bolt joints connecting the struts to the uprights require separate verification. When considering earthquakes, these verifications typically fail.

3. Tie Rod Joints

The back tie rods and horizontal tie rods themselves generally pass the verification, but the bolt joints at the ends of the tie rods require separate verification. When considering earthquakes, special design and construction are necessary.

4. Column Base Joints

Compression verification of column base joints.

5. Uplift Force

When the rack is unloaded and subjected to horizontal thrust at the top, or under combined loads including earthquake conditions, the uplift force of the column base joints needs to be verified to prevent the rack from overturning.