Common Fault Analysis of Beam Racking
News

Common Fault Analysis of Beam Racking

2026-02-26

Common faults of beam racking and their causes are mainly as follows:

I. Problems with component design and material selection

1. Inappropriate material selection

For example, beams and hanging plates should be made of steel of at least Q235B grade. In low-temperature cold storage, *** steel (such as grade C or D) should be selected.

2. Inappropriate specification selection

For example, a 120*50*1.5 double C welded beam should be selected, but a smaller specification was chosen instead.

Common Fault Analysis of Beam Racking.jpg

II. Significant defects in component processing quality

1. Cracks and fissures appear in the hanging plate teeth during forming

Although steel processing can cause micro-cracks that are not visible to the naked eye, hanging plates are generally formed by stamping and cold bending, resulting in a high strain rate during forming. This can lead to the formation of large-scale cracks (still invisible to the naked eye) in the steel at the root of the hanging plate. The presence of cracks does not mean the steel will immediately break; the hanging plate will only break when the crack extends to a certain extent. This means that the beams are initially usable and pass load tests. However, with prolonged use, the stress cycles from loading and unloading reach a certain level, causing cracks to build up and eventually leading to tooth breakage. This damage is sudden and without warning.

As long as the material's cold bending performance and processing technology meet certain requirements, the teeth should not have problems. So, can such accidents be prevented through inspection? The reality is no. Even if cracks at the tooth root are detected using various flaw detection techniques, there is currently no quantitative standard to determine if the teeth are defective. Until new standards are established, only regular inspections can be recommended. Once an accident occurs and it is determined to be caused by a defective tooth, immediate measures should be taken for the entire batch of beams, including but not limited to reinforcement, load reduction, and scrapping.

2. Incomplete or inadequate welds at the weld between the hanging plate and the beam.

The standard practice is for the hanging plate to be welded to the beam on all four sides, but in practice, three-sided or even two-sided welding is sometimes used. Regardless of the method, the rack designer is responsible for determining and implementing this. Under the premise of a qualified design, incomplete or inadequate welds should not be present.

III. Defects in Component Installation

1. The hanging teeth of the hanging plate are not fully or partially engaged in the hole of the column.

2. The overall height of the first-floor beam or the height of both ends is misaligned.

3. The pin is missing or the installation specifications are mismatched.

IV. Improper Use or Misoperation of Components

1. Overload or concentrated load storage.

2. Irreversible deformation and damage caused by collisions during operation.

3. The pin is removed or knocked off during use.

The process of a beam collapse accident caused by the missing *** pin is generally as follows:

(1) The pin at one end of the beam is missing and is not discovered in time. During the storage and retrieval process, the hanging teeth at that end of the beam fall out of the hole of the column, resulting in a loose hanging, which is still not discovered.

(2) When the goods are placed again, the loosely hung end of the beam is suspended, causing it to become a cantilever beam. The hanging plate at the other end bears all the load, resulting in a very large bending moment, which causes the hanging teeth at this end of the hanging plate to be damaged, and the hanging plate to bend significantly. Simultaneously, the load is transferred to the column, causing the column hole wall to crack. The accident is characterized by: one end of the hanging plate remaining intact, with only the hanging teeth detached or deformed vertically; the column connected to this end of the hanging plate is undamaged; the other end of the hanging plate is visibly deformed, with the hanging teeth detached or deformed horizontally, and the column hole wall connected to this end of the hanging plate is torn.

4. No load warning sign was set up, and the permissible maximum load is uncertain.

5. Unconfirmed structural changes, such as adjusting floor height or relocation/reassembly.